DateTargetCorrection
2018.03.14page 110, caption of picture 205 is in Finnish.Dimensions that optimise risk and benefits of overhead ladders.
2018.03.20page 122, caption of picture 229 is in Finnish.An example of a traditional swing with 2 seats.
2018.03.20page 123, caption of picture 230 is in Finnish.An example of a traditional swing with more than 2 seats.
2018.03.20page 123, caption of picture 231 is in Finnish.An example of group swing with a single support point.
2018.03.20page 123, caption of picture 232 is in Finnish.An example of group swing with 2 support points.
2018.03.20page 123, caption of picture 233 is in Finnish.An example of a contact swing.
2018.03.20page 123, caption of picture 234 is in Finnish.An example of a swing attached to another item of equipment.
2018.05.14page 053, new indent before the firstGoals weighing 10 - 18 kg are tested with a force equal to 30 kg mass.
2018.06.17page 227, fourth last indent under paragraph 3 is real paragraphIn addition to...
- An inspector is...
- The risk level...
2018.06.17page 179, lower table, fourth last row, second column is in Finnish - Risk taking
- Challenging climbing activities
- A slide over 2200 mm high
2018.07.17page 175, paragraph 129, first indentThe table size is 2740 mm x 1525 mm.
2018.07.18page 027, paragraph 11Inspector
The Inspector carrying out the post installation inspection...
2018.08.13page 120, paragraph 3 starting "Adventure playgrounds..." together with three indents after that should be indents under paragraph 2.EN 1176 is not applicable to:
- Adventure playgrounds which are…
- Play equipment connected to water.
- Toys for domestic use.
- Play equipment connected to electricity.
2018.08.14page 150, paragraphs 148 and 149"Paragraph 148" should be an empty row. Paragraph 149 is a sub-title for paragraphs 150 - 154.
2018.08.14page 150, pictures 291 and 290These two pictures have swapped their places.
2018.08.14page 155, paragraphs 189 - 193These paragraphs belong to the Case starting before paragraph 189.
2018.09.09Page 314, paragraph about EN 16899 clause 4.2.5.Remove "4.2.5" since this line and following three lines should refer to 5.3.
2018.09.09Page 315, paragraph about EN 16899 clause 4.4.8.Instead of "4.8.4." should be "5.8.4."
2018.09.11Page 137, Tip under chapter "Moving parts"...bringing 70 kg mass to the playground is not feasible.
2018.10.08Page 173, paragraph 115...measured without applying pressure to the measuring device.
2019.01.29Page 169, paragraph 75, fourth indentBar or rail … minimum step size is 700 mm.
2019.04.30Page 128, caption of picture 242c > a + 0.05 x b
2019.04.30Page 133, table "The difference between types 1 and 2", first column, last row is in Finnish.Extent of safety area
2019.04.30Page 90, paragraph 107, first indentBouncing facility: 1500 mm
2019.04.30Page 91, paragraph 108, first sub-indent under the fifth indentCable-way: always at least 1000 mm
- For seating type: the seat height minus 1000 mm
2019.05.13Page 107, paragraph 17Both Rungs, and vertical posts or additional hand rails shall should meet grasp requirements or alternatively an additional handrail with grip should be provided.
2019.05.13Page 140, caption of picture 337>1800 mm
2019.05.13Page 212, table> 60 40 %
> 30 - 60 40 %
> 5 - 30 20 %
< 5 %
2019.06.26Page 006, EN 1176-10 and EN 1176-11Both standards were published in 2008, not in 1998.
2019.06.28Page 90, paragraph 107, first indentBouncing facility: 600 1500 mm
2019.07.15Page 159, paragraph 27, first indentStainless steel cannot be used as grinding surfaces.
2019.07.17Page 222, paragraph 03 third indent...their barriers will be higher than 700 mm.
2019.07.22Page 303, ref 4.2.16.1, 9th partThe ground clearance for a <1.44 m2
bouncing facility is 1000 mm...
2019.07.22Page 303, ref 4.2.16.1, 10th partThe ground clearance for a ≥1.44 m2
bouncing facility is 2300 mm...
2020.09.13Page 080, paragraph 50...is inclined at less than 45° 38° and...
2022,04,28Page 215, after paragraph 15Added new paragraph: "There is less need for running detterent at the ends of the safety area. If a fence is located there for any reason, it should be positioned at least 1000 mm from the safety area."